WISE-5800
envelopeE-mail this Product
Product Reference & Support :
  • User's Manual
  • Quick Start
  • Cut Sheet
  • Introduction
  • Firmware
  • miniOS7 Utility
  • Log on Change Documentation
  • CE Certification
  • FCC Certification
  • RS-485 Based Data Acquisition Modules

  • User-defined I/O & Data Logger Module Communicable over Modbus TCP. Supports 1 XW I/O expansion board inside and up to 16 RS-485 based I-7000 modules or Modbus RTU devices.
    Product Pricing:
    WISE-5800: $599.00  add to cart
    Please Call 1-888-971-9888 for Volume and OEM discount pricing!
    Features

    WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.

    WISE-5800 supports an I/O expansion bus to implement various I/O functions such as D/I, D/O, A/D and D/A according to the XW-Board. In addition, WISE-5800 also support ICP DAS I-7000 remote I/O modules. Based on the variety I/O module of I-7000, WISE-5800 can provide user more flexibility in application field.

    WISE-5800 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It include all advantages which WISE series controllers can provide. In addition, WISE-5800 provide data logger function with microSD card, it can record I/O channel value by event trigger or regular time period. The data files can be sent back by Email or FTP. All setting can be completed through browser.

    Features

    • Built-in Web Server for IF-THEN-ELSE rule setting
    • Built-in IF-THEN-ELSE rule enigne for logic operation
    • Support IO, Counter, Timer, Schedule, Email, Recipe operations
    • No more programming. Just click and get done!
    • Data logger and data files send back function supported
    • Modbus TCP Protocol for SCADA Software Seamless Integration
    • 10/100 Base-TX Ethernet
    • Support XW-Board
    • Support I-7000 Remote I/O Modules(Up to 16)
    • SNTP Time Synchronization Supported

    Applications

    Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.

    WISE System Architecture

    WISE 5800 Facility Management

    WISE 5800 Pages

    Specifications & Additional Information
    CPU Module
    CPU 16-bit CPU
    SRAM 768 KB
    Flash 512 KB
    EEPROM 16 KB
    NVRAM 31 Bytes
    microSD Expansion Yes, can support 1 or 2 GB microSD
    RTC (Real Time Clock) RTC Provide seconds, minutes, hours, date of week/month; month and year
    Watchdog Timers Yes (0.8 second)
    Communication Ports
    Ethernet RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
    COM 1 RS-232 (Reserved, Unsupported by WISE firmware)
    COM 2 RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max.
    LED Indicators
    System LED Yes (Red)
    Ethernet Link LED Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received)
    LED Display -
    Hardware Expansion
    I/O Expansion Bus Yes
    Mechanical
    Dimensions (W x H x D) 91 mm x 123 mm x 52 mm
    Installation DIN-Rail
    Environment
    Operating Temperature -25 ~ +75 °C
    Storage Temperature -40 ~ +80 °C
    Ambient Relative Humidity 5 ~ 90% RH (non-condensing)
    Power
    Protection Power reverse polarity protection
    Frame Ground Yes (for ESD Protection)
    Input Range +12 ~ +48 VDC
    Redundant Power Input Yes
    Power Consumption 2.0 W

    Software Specifications

    Functions
    Rule Configuration Website Access Web server on WISE controllers to edit and upload logic rules through web browser.
    36 IF-THEN-ELSE Logic Rules 3 IF conditions with AND or OR operators
    3 THEN actions and 3 ELSE actions
    48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address.
    12 Timers Delay / Timing functions.
    12 Schedules Setup prescheduled routine tasks.
    12 Emails Send Email messages to pre-set Email receivers.
    12 CGI Commands Send pre-set CGI commands.
    12 Recipes Set up THEN/ELSE action groups.
    Data Logger Set up the Data Logger configuration, include the data record format, and data file sending operation.
    Modbus/TCP Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software.
    IF Conditions
    DI Channel ON、OFF、ON to OFF、OFF to ON、Change
    AI Channel =、>、<、>=、<=(value)
    Internal Register
    DI Counter =、>、<、>=、<=(value)、Change
    Timer Timeout、Not Timeout
    Schedule In Range、Out of Range
    Rule Status Enable、Disable
    THEN / ELSE Actions
    DO Channel ON、OFF、Pulse Output (Just for XW-Board)
    AO Channel Change the value
    Internal Register
    DI Counter Reset
    Timer Start、Reset
    Schedule Enable、Disable
    Email Send
    CGI Commands
    Recipe Execute
    Data Logger Start、Stop、One-Time Log
    Rule Status Enable、Disable
    Related Products
    I-7044
    4 Channel Isolated Digital Input and 8 Channel Isolated Digital Output Data Acquisition Module communicable over RS-485

    More Info
    I-7060
    4 Channel Isolated Digital Input and 4 Channel Relay Output Data Acquisition Module communicable over RS-485

    More Info
    GPSU06U-6
    24V/0.25A (max) Power Supply

    More Info
    DIN-KA52F-48
    48V/0.52A, 25 W Power Supply with Din-Rail Mounting

    More Info
    I-3625-ENC
    Large IP66 Industrial Enclosure with Dimensions 360 x 254 x 165mm

    More Info
    I-950-ENC IP66
    Small Industrial Enclosure with dimensions 254mm x 180mm x 90mm

    More Info
    WISE-7144
    8-channel Isolated Sink Type Open Collector Output and 8-channel Isolated Digital Input PoE Module, web browser configurable, allows users to implement IF-Then Else If type control logic and communicable over Modbus TCP

    More Info
    WISE-7901
    User-defined I/O Expansion PoE Module, web browser configurable, allows users to implement IF-Then Else If type control logic and communicable over Modbus TCP

    More Info
    image spacer image spacer image spacer image spacer image spacer image spacer image spacer image spacer
    Parent Site  Site Map  Policies  E-Commerce Information  Online Demo  Links  Press  FAQS  Solution Providers
    © 2010 ICP DAS USA. All rights reserved.