| WISE-5800 |
|
| Product Reference & Support : |
|
| User-defined I/O & Data Logger Module Communicable over Modbus TCP. Supports 1 XW I/O expansion board inside and up to 16 RS-485 based I-7000 modules or Modbus RTU devices. |
WISE-5800: $599.00
|
|
|
|
WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
WISE-5800 supports an I/O expansion bus to implement various I/O functions such as D/I, D/O, A/D and D/A according to the XW-Board. In addition, WISE-5800 also support ICP DAS I-7000 remote I/O modules. Based on the variety I/O module of I-7000, WISE-5800 can provide user more flexibility in application field.
WISE-5800 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It include all advantages which WISE series controllers can provide. In addition, WISE-5800 provide data logger function with microSD card, it can record I/O channel value by event trigger or regular time period. The data files can be sent back by Email or FTP. All setting can be completed through browser.
Features
- Built-in Web Server for IF-THEN-ELSE rule setting
- Built-in IF-THEN-ELSE rule enigne for logic operation
- Support IO, Counter, Timer, Schedule, Email, Recipe operations
- No more programming. Just click and get done!
- Data logger and data files send back function supported
- Modbus TCP Protocol for SCADA Software Seamless Integration
- 10/100 Base-TX Ethernet
- Support XW-Board
- Support I-7000 Remote I/O Modules(Up to 16)
- SNTP Time Synchronization Supported
Applications
Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.



|
| Specifications & Additional Information |
|
| CPU Module |
| CPU |
16-bit CPU |
| SRAM |
768 KB |
| Flash |
512 KB |
| EEPROM |
16 KB |
| NVRAM |
31 Bytes |
| microSD Expansion |
Yes, can support 1 or 2 GB microSD |
| RTC (Real Time Clock) |
RTC Provide seconds, minutes, hours, date of week/month; month and year |
| Watchdog Timers |
Yes (0.8 second) |
| Communication Ports |
| Ethernet |
RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators) |
| COM 1 |
RS-232 (Reserved, Unsupported by WISE firmware) |
| COM 2 |
RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max. |
| LED Indicators |
| System LED |
Yes (Red) |
| Ethernet Link LED |
Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received) |
| LED Display |
- |
| Hardware Expansion |
| I/O Expansion Bus |
Yes |
| Mechanical |
| Dimensions (W x H x D) |
91 mm x 123 mm x 52 mm |
| Installation |
DIN-Rail |
| Environment |
| Operating Temperature |
-25 ~ +75 °C |
| Storage Temperature |
-40 ~ +80 °C |
| Ambient Relative Humidity |
5 ~ 90% RH (non-condensing) |
| Power |
| Protection |
Power reverse polarity protection |
| Frame Ground |
Yes (for ESD Protection) |
| Input Range |
+12 ~ +48 VDC |
| Redundant Power Input |
Yes |
| Power Consumption |
2.0 W |
Software Specifications
| Functions |
| Rule Configuration Website |
Access Web server on WISE controllers to edit and upload logic rules through web browser.
|
| 36 IF-THEN-ELSE Logic Rules |
3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
|
| 48 Internal Registers |
Hold temporary variables and read/write data via Modbus/TCP address.
|
| 12 Timers |
Delay / Timing functions.
|
| 12 Schedules |
Setup prescheduled routine tasks.
|
| 12 Emails |
Send Email messages to pre-set Email receivers.
|
| 12 CGI Commands |
Send pre-set CGI commands.
|
| 12 Recipes |
Set up THEN/ELSE action groups.
|
| Data Logger |
Set up the Data Logger configuration, include the data record format, and data file sending operation.
|
| Modbus/TCP Protocol |
Real time control and monitoring I/O channels and system status of controllers via SCADA software.
|
| IF Conditions |
| DI Channel |
ON、OFF、ON to OFF、OFF to ON、Change |
| AI Channel |
=、>、<、>=、<=(value) |
| Internal Register |
| DI Counter |
=、>、<、>=、<=(value)、Change |
| Timer |
Timeout、Not Timeout |
| Schedule |
In Range、Out of Range |
| Rule Status |
Enable、Disable |
| THEN / ELSE Actions |
| DO Channel |
ON、OFF、Pulse Output (Just for XW-Board) |
| AO Channel |
Change the value |
| Internal Register |
| DI Counter |
Reset |
| Timer |
Start、Reset |
| Schedule |
Enable、Disable |
| Email |
Send |
| CGI Commands |
| Recipe |
Execute |
| Data Logger |
Start、Stop、One-Time Log |
| Rule Status |
Enable、Disable |
|
|
|
I-7044 4 Channel Isolated Digital Input and 8 Channel Isolated Digital Output Data Acquisition Module communicable over RS-485
 More Info |
I-7060 4 Channel Isolated Digital Input and 4 Channel Relay Output Data Acquisition Module communicable over RS-485
 More Info |
GPSU06U-6 24V/0.25A (max) Power Supply
 More Info |
DIN-KA52F-48 48V/0.52A, 25 W Power Supply with Din-Rail Mounting
 More Info |
I-3625-ENC Large IP66 Industrial Enclosure with Dimensions 360 x 254 x 165mm
 More Info |
I-950-ENC IP66 Small Industrial Enclosure with dimensions 254mm x 180mm x 90mm
 More Info |
WISE-7144 8-channel Isolated Sink Type Open Collector Output and 8-channel Isolated Digital Input PoE Module, web browser configurable, allows users to implement IF-Then Else If type control logic and communicable over Modbus TCP
 More Info |
WISE-7901 User-defined I/O Expansion PoE Module, web browser configurable, allows users to implement IF-Then Else If type control logic and communicable over Modbus TCP
 More Info |
|